Automation recipes
Better Thermostat gives each room a few settings that an automation can change: the Pause Learning, Window Detection and Release devices switches, the Outdoor Temperature Threshold and Tolerance numbers, the presets, the HVAC mode and the better_thermostat.run_valve_maintenance action. When to change them is up to you. A boiler that heats hot water, a lit fireplace or a sunny afternoon with surplus solar power are things Home Assistant knows about and Better Thermostat does not, so the decision belongs in an automation.
This page collects those automations by what you want to achieve. Where another page already has the recipe, it links there.
Add an automation under Settings → Automations & Scenes, in YAML mode. The entity IDs below are examples: Better Thermostat names its entities after the device, so a device called Living room has climate.living_room, switch.living_room_pause_learning, switch.living_room_window_detection, switch.living_room_release_devices and number.living_room_outdoor_temperature_threshold. Look yours up on the device page. A device with a cooler has the HVAC modes heat_cool and off instead of heat and off; use heat_cool in the recipes below for such a room.
Keep the learned values clean
Section titled “Keep the learned values clean”When the room warms or cools for a reason Better Thermostat cannot see, turn Pause Learning on. Regulation carries on, but nothing is learned until the switch is off again. Pausing learning explains the switch and has the recipes:
- When the boiler heats hot water or the heat source is locked out, pause learning for that time: The boiler heats hot water, or the Pause learning while the heat source delivers no heat blueprint.
- When a fireplace or stove warms the room, pause learning in that room and the ones next to it: A fireplace is lit, or the Pause learning while the fireplace burns blueprint, which can also set a preset while the fire burns.
- When a holiday home sits at frost protection for weeks, pause learning while it does: Away or frost protection for weeks.
Heat less while nobody is in the room
Section titled “Heat less while nobody is in the room”When the house or a single room is empty, set the Away preset and go back to your normal preset when someone is there again. The Away preset when nobody is home blueprint does this. It takes person and device_tracker entities for the whole house, or a room’s occupancy binary_sensor for one room, and waits a delay you choose before it lowers the temperature. Set the Away temperature on the device; see Presets. Window and door sensors keep working alongside it.
Decide yourself what an open window does
Section titled “Decide yourself what an open window does”The Window Detection switch decides whether the window and door sensors turn the heating off. Turning window detection off describes it and has the recipes:
- When you want the Eco temperature instead of switching off, for TRVs that drain their battery when switched off: Lower the temperature instead of switching off.
- When you have closed the window and want heat now, without waiting for the close delay: A button that resumes heating now.
- When you want to heat with the window ajar, or a window sensor is stuck on open, turn Window Detection off from a dashboard and let an automation turn it back on later: Ignore a faulty window sensor.
Never let the room get colder than a minimum
Section titled “Never let the room get colder than a minimum”When the room must not drop below a minimum, whatever a window sensor or the outdoor temperature says, override both while the room is too cold. This automation turns Window Detection off and raises the Outdoor Temperature Threshold to 40 °C, above the damped outdoor temperature you can expect, once the room has been below 15 °C for ten minutes. Once it is back above 17 °C, it turns detection on again and puts the threshold back to 18 °C, the value you normally use:
alias: Living room never below 15 °Ctriggers: - trigger: numeric_state entity_id: climate.living_room attribute: current_temperature below: 15 for: minutes: 10 id: too_cold - trigger: numeric_state entity_id: climate.living_room attribute: current_temperature above: 17 for: minutes: 10 id: warm_againactions: - choose: - conditions: - condition: trigger id: too_cold sequence: - action: switch.turn_off target: entity_id: switch.living_room_window_detection - action: number.set_value target: entity_id: number.living_room_outdoor_temperature_threshold data: value: 40 - conditions: - condition: trigger id: warm_again sequence: - action: switch.turn_on target: entity_id: switch.living_room_window_detection - action: number.set_value target: entity_id: number.living_room_outdoor_temperature_threshold data: value: 18The room heats to its target temperature, so the target has to be above the minimum, and the thermostat has to be in heat. The Window Detection switch exists only for a device with a window or door sensor, and the threshold number only for one with an outdoor sensor or a weather entity; leave out the steps for the entity your device does not have. All temperatures in the automation are in your system’s temperature unit; with Fahrenheit, use 59, 63, 64 and 104 instead of 15, 17, 18 and 40. A damped outdoor temperature at or above the raised threshold still switches the heating off, so pick a value above anything your climate reaches. The threshold steps act at once, because Better Thermostat checks the outdoor temperature again as soon as the threshold changes. A weather entity that stops giving a forecast needs no recipe: after three hours without one, the room heats until the forecast is back. See Summer mode.
Switch the heating off for the summer
Section titled “Switch the heating off for the summer”When the heating stays off from spring to autumn, whatever the weather on a single day, switch the thermostats off with a helper. Create a toggle helper called Heating season and switch it from a dashboard:
alias: Heating seasontriggers: - trigger: state entity_id: input_boolean.heating_season to: - "on" - "off"actions: - action: climate.set_hvac_mode target: entity_id: - climate.living_room - climate.bedroom data: hvac_mode: "{{ 'heat' if trigger.to_state.state == 'on' else 'off' }}"To switch on fixed dates, let a second automation set the helper, here on 1 May and 1 October. It also sets the helper when Home Assistant starts on one of those days, and leaves it to the dashboard on every other day:
alias: Heating season by datetriggers: - trigger: template value_template: "{{ now().day == 1 and now().month in [5, 10] }}" - trigger: homeassistant event: startconditions: - condition: template value_template: "{{ now().day == 1 and now().month in [5, 10] }}"actions: - action: "input_boolean.turn_{{ 'off' if now().month == 5 else 'on' }}" target: entity_id: input_boolean.heating_seasonKeeping the valves moving does not need the heating on. A TRV with If your thermostat has no own maintenance mode, you can use this one enabled is opened and closed about once a week, more often for some TRV models, while its thermostat is off, too. To exercise the valves at a time of your choosing instead, call the action from an automation of your own:
action: better_thermostat.run_valve_maintenancetarget: entity_id: - climate.living_room - climate.bedroomIt fails for a thermostat with no TRV that has maintenance enabled; see Actions and conditions.
Run the devices yourself for a while
Section titled “Run the devices yourself for a while”When you want to hold radiators open for maintenance or over the summer, run an air conditioner by hand while Better Thermostat is off, or let it run a self-cleaning sequence, turn Release devices on for that time; to run a single radiator yourself, turn on its own Release switch. Releasing the devices has a recipe for each.
Use the outdoor temperature
Section titled “Use the outdoor temperature”The Outdoor Temperature Threshold stops the heating while a damped outdoor temperature, averaged over about a day, is above it. To change it from an automation or use one threshold for several rooms, see Changing the threshold.
Stop heating while it is nearly as warm outside as the target
Section titled “Stop heating while it is nearly as warm outside as the target”When you want the heating off on a warm afternoon, compare the current outdoor temperature with the room’s target. This automation switches the thermostat off once it is less than 2 °C colder outside than the target, and back on once the gap is more than 3 °C:
alias: Living room off while it is warm outsidetriggers: - trigger: template value_template: >- {{ states('sensor.outdoor_temperature') | float(-100) > state_attr('climate.living_room', 'temperature') | float(100) - 2 }} for: minutes: 15 id: warm - trigger: template value_template: >- {{ states('sensor.outdoor_temperature') | float(100) < state_attr('climate.living_room', 'temperature') | float(-100) - 3 }} for: minutes: 15 id: coldconditions: - condition: template value_template: "{{ trigger.id == 'warm' or is_state('climate.living_room', 'off') }}"actions: - action: climate.set_hvac_mode target: entity_id: climate.living_room data: hvac_mode: "{{ 'off' if trigger.id == 'warm' else 'heat' }}"The thermostat keeps its target while it is off, so the second trigger can still compare with it. The automation switches the thermostat back on even when you switched it off yourself; turn the automation off for as long as the room should stay off. The float defaults make a missing outdoor reading count as neither warm nor cold. The gaps of 2 and 3 are in your system’s temperature unit; with Fahrenheit, use 4 and 5, rounded from 3.6 and 5.4. For a room with a cooler, use target_temp_low instead of temperature and heat_cool instead of heat.
Heat with the air conditioner while the sun provides the power
Section titled “Heat with the air conditioner while the sun provides the power”When an air conditioner can heat the room more cheaply than the radiators while there is surplus solar power, set up two Better Thermostat devices for the room: one with the radiators’ TRVs, one with the air conditioner as its thermostat. This automation keeps exactly one of them in heat. The air conditioner takes over once the surplus has stayed above 1.5 kW for ten minutes while it is warmer than 3 °C outside; the radiators take over again when the surplus has dropped below 0.8 kW for ten minutes or it gets colder than 3 °C outside. When Home Assistant starts, it picks the device from the current readings, and changes nothing while the readings are missing or between the thresholds:
alias: Living room heats with surplus solar powermode: queuedtriggers: - trigger: template value_template: >- {{ states('sensor.solar_surplus_power') | float(0) > 1500 and states('sensor.outdoor_temperature') | float(-100) > 3 }} for: minutes: 10 id: surplus - trigger: numeric_state entity_id: sensor.solar_surplus_power below: 800 for: minutes: 10 id: no_surplus - trigger: numeric_state entity_id: sensor.outdoor_temperature below: 3 id: no_surplus - trigger: homeassistant event: start id: startvariables: surplus: "{{ states('sensor.solar_surplus_power') | float(none) }}" outdoor: "{{ states('sensor.outdoor_temperature') | float(none) }}" heating_device: >- {% if trigger.id == 'surplus' %}climate.living_room_ac {% elif trigger.id == 'no_surplus' %}climate.living_room_radiators {% elif surplus is not none and outdoor is not none and surplus > 1500 and outdoor > 3 %}climate.living_room_ac {% elif (surplus is not none and surplus < 800) or (outdoor is not none and outdoor < 3) %}climate.living_room_radiators {% endif %}conditions: - condition: template value_template: "{{ heating_device != '' }}"actions: - action: climate.set_hvac_mode target: entity_id: "{{ heating_device }}" data: hvac_mode: heat - action: climate.set_hvac_mode target: entity_id: >- {{ 'climate.living_room_radiators' if heating_device == 'climate.living_room_ac' else 'climate.living_room_ac' }} data: hvac_mode: "off"The outdoor limit of 3 is in the unit of the outdoor sensor’s state in Home Assistant. Home Assistant converts temperature sensors to the system unit unless you set another unit on the sensor. When that state is in °F, use 37 instead, rounded from 37.4. Give both devices the same room temperature sensor and the same target, and the air conditioner’s device the calibration type Target Temperature Based. The device that is off switches its TRVs or its air conditioner off.
Keep the air conditioner from cooling
Section titled “Keep the air conditioner from cooling”When the air conditioner has a Better Thermostat device of its own, switching that device off keeps the air conditioner off, and the radiators of the room carry on; see Releasing the devices.
When the air conditioner is the cooler of the device that also drives the radiators, switching the device off would stop the radiators too. Raise the cooling target instead: Better Thermostat keeps the air conditioner off as long as the room is below that target, and heats to the heating target as before. This automation raises the cooling target to the highest value the device accepts at night, keeping the heating target, and puts back the evening’s targets and preset in the morning:
alias: Living room air conditioner quiet at nighttriggers: - trigger: time at: "22:00:00" id: night - trigger: time at: "07:00:00" id: morningactions: - choose: - conditions: - condition: trigger id: night sequence: - action: scene.create data: scene_id: living_room_before_night snapshot_entities: - climate.living_room - action: climate.set_temperature target: entity_id: climate.living_room data: target_temp_low: "{{ state_attr('climate.living_room', 'target_temp_low') }}" target_temp_high: "{{ state_attr('climate.living_room', 'max_temp') }}" - conditions: - condition: trigger id: morning sequence: - action: scene.turn_on target: entity_id: scene.living_room_before_nightBetter Thermostat limits the cooling target to the air conditioner’s own range, so a room that gets warmer than the air conditioner’s highest setting is still cooled. Setting a preset during the night brings back that preset’s cooling target. A scene made with scene.create is lost when Home Assistant restarts, so after a restart at night, set the targets in the morning yourself.
The same automation keeps the air conditioner from cooling in winter: trigger the first branch when the outdoor temperature drops below a value of your choice, and the second when it rises above it again.