TRVs are battery- and radio-constrained devices, and writes get lost on the air. Two mechanisms address this pair of facts: the write budget spaces writes out, the reconciler heals the ones that got lost. Deciding is never throttled; only the radio traffic is.

A cycle writes only differences: a device already matching the intent gets no write. For each TRV the shell translates the intent per channel (HVAC mode, setpoint, calibration offset, valve percentage) through the safety hull, the write budget, and finally the device adapter:

flowchart LR
    I[TrvDesired] --> H[Safety hull clamp]
    H --> B{Budget slot free or safety-relevant?}
    B -->|yes| A[Adapter / model quirk]
    B -->|no| D[Defer + schedule follow-up]
    A --> T[(TRV)]
    D -.->|budget reopens| RQ[request_control_cycle]

The setpoint is compared on the device’s grid. Before the comparison it is rounded onto the TRV’s step and clamped to its range, exactly as the adapter write would round and clamp it, so a target between two steps (70 °F is 21.11 °C) is written once and then matches the value the TRV holds instead of going out again every cycle.

Adapters (adapters/) speak the integration’s dialect: Zigbee2MQTT, deCONZ, Tado, ZHA, Z-Wave JS, Shelly, generic climate services. Zigbee2MQTT, ZHA, Z-Wave JS and the Shelly BLU TRV publish the valve as a number entity of its own, and adapters/valve_entity.py serves that valve channel for all four. Model quirks (model_fixes/) override single operations for devices that need special sequences (for example valve writes on the Sonoff TRVZB). The Trv object carries both, plus a TrvCapabilities descriptor derived in one place (whether the device supports offset writes, direct valve writes, and an OFF mode), so the rest of the code consults capabilities instead of probing quirk modules.

Home Assistant puts no time limit on a service call, and some integrations keep the call open until the device answers (a sleeping Z-Wave node, a cloud API without a request timeout). The heads of a room and the cooler are written one after another under one lock, so every device write, adapter, quirk and cooler alike, is bounded at 30 seconds (DEVICE_CALL_TIMEOUT_S). A write that runs out of time is cancelled and fails like one that raised: it is not repeated within the cycle, the channel is logged as out of reach, and each following cycle tries it once until a write goes through. The other heads of the room keep getting their writes. A head that stops answering still costs the room up to 30 seconds per channel it is written on (mode, setpoint, offset, valve) in every cycle.

A mode write that ran out of time may still reach the device: a sleeping node keeps the command queued and applies it when it wakes. Such a mode is remembered as withdrawn for the confirmation window, like a command the room took back before the device confirmed it, so the device applying it late is not read as someone switching the mode at the device. The head’s setpoint and offset are still written in the same cycle.

At startup, each TRV’s initial tweak has a 60-second budget; a TRV whose tweak runs out of time counts as failed and the startup moves on.

While the Release devices switch is on, the kernel’s intent is marked as released and addresses no device. A control cycle then neither controls a TRV nor runs the cooling channel, and the reconciler queues nothing. The writes outside the control cycle stand down as well: the external room temperature and its keepalive, the steps of a valve maintenance run, the child lock, and the initialisation of a TRV at startup, which waits for the devices to be taken back. A cycle decides once and then awaits its writes one after the other, so each TRV and cooler write, and each write of a TRV’s initialisation, checks the switch itself right before it goes out: a release that comes in while a cycle or an initialisation is under way ends the writes that follow, and a write already sent completes. The same holds inside a write: each attempt of the retry chain, the next valve channel, the mode an offset write restores, the preset or sensor selector a model quirk pairs with its command, the deferred close after a TRVZB valve bump, and the external temperature for the next TRV each check the switch before they go out. Taking them back requests one control cycle, which writes the differences like any other.

A TRV released on its own goes through the same checks, keyed by its entity id: every write above asks whether the room’s devices or this TRV are released (device_released()), so a cycle and the writes outside it pass the released TRV over and serve the others. The kernel drops the TRV from its intents, the control queue does not dispatch it, the mode cache refresh at the end of a cycle and the reading of reports held during it leave it alone, and the reconciler, which compares only addressed TRVs, never sees it. A cooler that is also one of the room’s TRVs is released with it.

Non-safety writes to one TRV keep a minimum spacing of 30 seconds, per channel (setpoint, offset, valve), so one channel’s writes cannot starve another’s slot. A TRV with the HomematicIP option enabled gets ten minutes instead, since its head shares the access point’s 1 % radio duty cycle; the first setpoint write after the user changes the target or mode still goes out at the 30-second pace. HVAC-mode commands, OFF included, do not go through the budget at all. Safety-relevant writes on a budgeted channel (the minimum setpoint that stands in for OFF on a TRV without an off mode, frost-floor rewrites, closing the valve) always bypass the budget but still stamp the slot, so the spacing stays accurate.

A deferred write is not dropped on any of the three channels: the defer path schedules one coalesced control cycle for the moment the budget reopens, and that cycle re-derives the value. A valve write the device rejected after the budget was spent schedules the same catch-up cycle. The follow-up is needed because the reconciler compares against the last value actually written, which the device still matches.

The valve write decision skips a write only when the last value sent equals the target and the entities that write set still report it, or report nothing it could be checked against. A valve entity whose state is assumed_state only repeats what was sent, so every cycle asks for the write again, and it goes out whenever the valve channel’s budget allows. That holds for a close as well: a repeated close that only an assumed state reports waits for its slot instead of bypassing the budget. A closed valve the device reports open again is closed again at once, once per report; the next close waits for the device’s next position report.

The setpoint write decision compares the intent with the setpoint the device reports, not with the last value sent, so a setpoint the device did not take is written again by the next cycle. A device that keeps reporting something else would be written on every cycle, so the setpoint channel backs off: the writes since the device was last seen holding, within one of its steps, the intended or the last written value form a run. The second write of a run follows at the channel’s interval, and every further one waits twice as long as the one before, up to one hour. A user change of target or mode since the last write skips the backoff once. After six writes of a run the TRV is listed in the thermostat’s errors attribute and gets a setpoint_not_applied repair issue; both go away when the device is seen holding the value. A report without a readable setpoint neither extends nor ends a run.

The offset channel writes no differently when the offset runs out of range, but it watches for that. A cycle continues a run of such cycles (core/offset_limit.py) when its offset intent, after the safety hull, and the reported offset both lie within one offset step of the same limit of the range the hull clamps to, and the correction the gap between room temperature and TRV reading asks for (the gap plus the offset held, or the negated gap for a TRV that shifts its setpoint) lies more than a step past that limit. A calibration mode or overheating protection that holds the offset at a limit on a TRV that applies it leaves that correction inside the range. A run that lasts an hour gives the TRV a calibration_offset_at_limit repair issue and logs one warning; a cycle that finds any of the three otherwise ends the run and takes the issue back. The run comes off the TRV at the start of every control_trv call and goes back only through the offset block, so a cycle that returns early or follows no offset ends it, and a raised issue stays in place. An offset entity that is unavailable or unknown counts as no report.

Every five minutes, reconcile_tick runs the same observe-decide step as a control cycle (without a flight-recorder entry) and compares the intent against what the devices report:

  • mode — an OFF intent against a device reporting a heating mode (devices that cannot switch off legitimately stay in a heating mode at their minimum temperature and are compared by setpoint instead), and a heating intent against a device reporting OFF,
  • setpoint — the last commanded value against the reported target, with a tolerance of half the device-reported step (at least 0.05 K), so firmware snapping a value onto its own coarser grid still counts as a match,
  • offset — the commanded calibration against the calibration entity, once the device confirmed the last write (in-flight writes remain the write path’s business),
  • valve — what the last valve write sent against every entity it set, in that entity’s own units. An adapter write is read back from the valve number entity, against the commanded percentage scaled onto the min, max and step that entity publishes, exactly as the write scaled it; a quirk write from the numbers the quirk names, such as both the opening and the closing degree of a Sonoff TRVZB, against the values the quirk sent. The tolerance is 5 % of the entity’s range either way, and at least one step below: ZHA truncates a number onto its grid, so a write can land one step below the value sent, while no device rounds a value already on the grid upwards. An entity that publishes no usable range is not read. An entity whose state is assumed_state repeats the last command sent to it, so a matching one confirms nothing and is no divergence either; a different one means a later command replaced BT’s,
  • cooler mode — the mode a cooler of its own reports against the COOL or OFF the cooling channel last decided. A cooler that also carries the heating role is compared as a TRV instead.

On divergence the reconciler queues one ordinary control cycle, the general healing mechanism that replaces per-case keepalives. The tolerances matter: a reconciler that fights device quantization or normal modulation would re-send the same value every five minutes and drain batteries, which is what the budget exists to prevent.

The same tick hosts the watchdog check: if no control cycle completed for 15 minutes, it logs an error and forces one. A cycle that is still running 15 minutes after it began is logged as an error once.