Degraded mode

Better Thermostat raises a degraded mode repair issue when one of the sensors it was configured with becomes unavailable: the room temperature sensor, the window sensor, the door sensor, the humidity sensor, the outdoor sensor, or the weather entity. An unavailable cooling device counts as well. The thermostat keeps running; the issue tells you that it is working with less information than you configured.

During the first five minutes after startup the warning is suppressed so that slow integrations (for example cloud-based weather providers) get time to come online before you see it.

Better Thermostat degrades step by step instead of stopping. The control quality steps down a ladder, one rung at a time:

  1. Optimal — the room sensor delivers; everything works as configured.
  2. Sensor fallback — the room temperature sensor is unavailable, but at least one TRV reports its internal temperature. Better Thermostat then controls on the average of the TRV-internal temperatures. TRVs measure next to the hot valve, so expect less accuracy, but it is still better than controlling on a frozen last reading.
  3. Hold — neither the room sensor nor any TRV temperature is usable (for example during a Zigbee outage). The controller stops adjusting and the TRVs keep their last commanded state. Frost protection stays enforced on every write.

For a device using its valve as the only actuator, such as a Shelly BLU TRV under Direct Valve Based control, HOLD requests a fixed emergency opening of 25% because its own thermostat cannot take over. This preserves limited heating without retaining a potentially fully open valve. Boost does not override this opening. OFF and open windows or doors still close the valve, as does an invalid stored calibration mode, which raises a separate repair issue. BT uses the normal write and retry path and resumes regulation after the sensor-recovery stability period. The device must remain reachable for the command to succeed. A fixed opening cannot guarantee frost protection and does not provide a local fallback during a Home Assistant or network outage.

TRVs that regulate on a room temperature Better Thermostat writes into them, such as the Sonoff TRVZB, stop receiving it while the room sensor gives no reading. Better Thermostat does not keep sending the sensor’s last value, so the TRV falls back to its own sensor after its own timeout (two hours on a TRVZB). The first reading after the outage is written to the TRV at once.

A rung steps down after the loss has persisted for about two minutes, and climbs back up after the sensors have been stable again for about five minutes, so short sensor flaps do not flip the behavior back and forth.

The Better Thermostat climate entity exposes the rung as the control_mode attribute (optimal, sensor_fallback, or hold), along with degraded_for_seconds (how long the degradation has lasted) and unavailable_sensors. The calibrator_health attribute reports per TRV the health of its calibration controller: healthy, non_finite (a learned value was not a number), oscillating, runaway_gains, or windup_suspect. Check them under Developer tools → States.

  • Check the listed sensors: battery, power, and whether the entity shows unavailable or unknown in Home Assistant.
  • For cloud-based weather or outdoor entities, check the integration that provides them.

The repair issue disappears on its own once all configured sensors are available again. Taking a sensor that is gone for good out of the Better Thermostat’s settings clears it as well.