Better Thermostat adds three actions of its own and two device conditions. Everything else, such as setting a target or a preset, goes through Home Assistant’s climate actions, which every Better Thermostat accepts.

Each action targets one or more Better Thermostat climate entities. You find them under Developer tools → Actions and in the automation editor under Add action → Better Thermostat.

Sets the heating power the thermostat has learned back to its starting value. The thermostat then learns it again from the next heating cycles; the current value is published in the heating_power attribute and the heating power sensor.

Use it after a change that makes the learned value wrong, such as a new radiator or a room sensor in a new place.

This action takes no fields.

action: better_thermostat.reset_heating_power
target:
entity_id: climate.living_room

Runs the valve maintenance cycle now instead of at its next scheduled time: each valve is opened and closed so it does not get stuck. Only valves with valve maintenance enabled in the thermostat’s settings take part.

The action fails with a message when no valve of the thermostat has maintenance enabled, or when a maintenance run is already in progress.

The action returns once the run has finished. If the thermostat is reloaded, disabled or deleted meanwhile, the run stops, puts each TRV back as it was before, and the action returns without an error.

This action takes no fields.

action: better_thermostat.run_valve_maintenance
target:
entity_id: climate.living_room

Clears everything the PID controller has learned for this thermostat, for every TRV and every target temperature. Without further fields the controller starts again from its built-in gains.

Field Required Description
apply_pid_defaults no When true, writes starting gains for the current target and the targets 0.5 °C above and below it, on every TRV. Default false.
defaults_kp no Proportional gain to write, 0 to 1000. Without it the built-in 60 is used.
defaults_ki no Integral gain to write, 0 to 2. Without it the built-in 0.01 is used.
defaults_kd no Derivative gain to write, 0 to 10000. Without it the built-in 2000 is used.

The three gain fields only take effect together with apply_pid_defaults. With apply_pid_defaults the thermostat needs a target temperature; without one the action fails and nothing is reset. The PID numbers on the device show the new gains as soon as the action has run.

action: better_thermostat.reset_pid_learnings
target:
entity_id: climate.living_room
data:
apply_pid_defaults: true
defaults_kp: 40

In the automation editor, Add condition → Device, a Better Thermostat device offers two conditions.

Condition type True while Values
is_hvac_mode The thermostat is in the chosen HVAC mode. off, heat, heat_cool
is_hvac_action The thermostat’s current action is the chosen one. off, heating, cooling, idle

The mode is what the thermostat is set to; the action is what it is doing right now. A thermostat set to heat reports idle while the room is warm enough. A thermostat reports cooling only when a cooler is configured.

condition: device
device_id: 0123456789abcdef0123456789abcdef
domain: better_thermostat
entity_id: climate.living_room
type: is_hvac_action
hvac_action: heating

The device triggers are described with the blueprints that use them, in How device triggers work.