# Safety and degradation

> The safety hull, the fail-soft ladder, the watchdog, and calibrator self-healing.

Source: https://better-thermostat.org/internals/safety-and-degradation/

Controlling worse is acceptable. Not controlling at all, or silently
hanging, is not. Every degradation is explicit, annunciated, and
reversible.

## The safety hull

Every outgoing value passes `core/safety.py` at the command boundary:
setpoints are clamped to the device's min/max including the frost
floor, calibration offsets to the device's calibration range, valve
percentages to 0..`valve_max_opening`. The hull is the *second* guard:
the calibration math keeps its own intermediate clamps for bit-exact
debuggability. But the hull owns the boundary, and no write path may
bypass it, including the valve close on an OFF intent.

Safety-relevant writes (OFF for an open window or absent heat demand,
frost-floor rewrites, closing the valve) also bypass the
[write budget](https://better-thermostat.org/internals/writes-and-reconciliation/): safety is never
throttled.

## The fail-soft ladder

```mermaid
stateDiagram-v2
    OPTIMAL --> SENSOR_FALLBACK: room sensor lost (~2 min debounce)
    SENSOR_FALLBACK --> HOLD: no TRV temperature usable either (~2 min)
    OPTIMAL --> HOLD: room sensor and TRV temperatures lost together (~2 min)
    HOLD --> SENSOR_FALLBACK: TRV temperatures back (~5 min stability)
    SENSOR_FALLBACK --> OPTIMAL: room sensor back (~5 min stability)
    HOLD --> OPTIMAL: room sensor back (~5 min stability)
```

The ladder does not have to pass through SENSOR_FALLBACK. It commits to
the rung the observation supports for the whole window, so losing the
room sensor and every TRV temperature at once goes straight to HOLD, and
a returning room sensor lifts HOLD straight to OPTIMAL.

- **OPTIMAL** — the external room sensor delivers; the control law
  works as configured.
- **SENSOR_FALLBACK** — the room sensor is unavailable, but at least
  one *reachable* TRV reports an internal temperature: calibration
  substitutes the mean of the TRV-internal readings. Controlling on a
  hot-valve sensor is worse than on a room sensor, but strictly better
  than controlling on a silently stale reading. A stored reading only
  counts while its TRV is actually reachable, and going unavailable
  invalidates it, so pre-outage values cannot pass as live.
- **HOLD** — neither the room sensor nor any TRV temperature is usable
  (for example during a Zigbee outage). The kernel emits the same
  heating intent as on every rung, with the user's target as the
  setpoint; the shell reads the rung and withholds calibration (no
  offsets, no valve percentages), so the setpoint reaches the device
  uncalibrated: the controller stops adjusting, each device stays
  locked on the last known target (re-sent if the device loses it), and
  the frost floor stays enforced on every write. Nothing downstream of
  the HOLD decision may re-introduce an adjustment, boost included. The
  only valve write on HOLD is the overheat-safe close: an OFF intent
  (room switched off, open window, no heat demand) closes the valve to
  0 % on a direct-valve TRV whose valve BT drives, by a calibration mode
  that writes the valve or by boost.
  A room switched off turns its devices off on HOLD as on every other
  rung: the last known target is not locked in, and a TRV without an OFF
  mode receives its minimum setpoint.

Downgrades are debounced (`down_debounce_seconds`, 120 s) so a flapping sensor
does not flip behavior; upgrades require sustained recovery
(`up_stability_seconds`, 300 s). A sensor that stops reporting produces no
events, so a periodic ladder tick (`LADDER_TICK_S`, 60 s) evaluates the
ladder in every configuration, and a rung commits at most one tick after
its window has elapsed. The rung is visible as the `control_mode`
attribute, along with `degraded_for_seconds` and `unavailable_sensors`;
entering degraded mode raises a repair issue that clears itself on
recovery.

Per-TRV, the bulkhead is the kernel's address filter: a dead TRV
receives no intent (unless boost heating is active) and its native
thermostat keeps controlling at the last commanded state, effectively
in passthrough mode, while the other TRVs stay fully controlled.

## The watchdog

`core/watchdog.py` answers one question: did a control cycle complete
recently? The heartbeat is stamped on every *deliberate* outcome of a
cycle, including skipping an unavailable TRV or deferring a write to
the budget, while error paths that bail out leave it alone. The
reconciler tick reads it: a device that diverges from the intent while
no cycle has completed for 15 minutes is a silent hang, which raises an
error and forces a cycle. A room whose devices hold the intent has
nothing for a cycle to do, so a loop that stays quiet there is not
reported, however long ago its last cycle ran. A running cycle holds the
reconciler off, so the tick also checks how long the current cycle has
been running: one that has not ended 15 minutes after it began is
logged as an error once. Valve maintenance holds the reconciler off on
purpose and is not counted.

## Calibrator self-healing and health

Self-healing applies where the pathology is unambiguous; everything
else is annunciation only:

| Pathology | Reaction | Threshold anchor |
|---|---|---|
| Non-finite values in learned state | Discard state, relearn from live data | none needed (NaN/Inf) |
| Runaway auto-tuned gains (PID) | Reset gains to defaults | configured gain ranges |
| Wound-up integrator (PID) | Reset integrator | actuator-derived integrator limits |
| Oscillating output | **Annunciate only** | ≥4 reversals between ≥20-point swings in the last 10 outputs |

Oscillation triggers no automatic gain backoff: a detector that backs
gains off on a false positive thrashes the controller, which is worse
than the oscillation it reacts to. Backoff stays a manual decision until
the detector is validated against the calibration benchmark. Every
verdict lands per TRV in the `calibrator_health`
attribute; a healthy verdict clears only the grades its reporter owns,
so the sanitize path and the oscillation watcher cannot flap each
other's annunciations.

Persisted state is hardened at three layers: deserialization skips a
wrong-typed field individually while a non-finite value resets the
whole stored entry to its defaults, an unreadable store yields
defaults instead of killing startup, and the sanitize step heals
whatever still reaches a controller. For a reset entry and an
unreadable store, load attempts to copy the stored payload aside
before the defaults apply. If that copy cannot be confirmed on disk,
the defaults still apply, but saves are held back and the copy is
retried, so the live store keeps the payload until the copy exists
(see [Persistence](https://better-thermostat.org/internals/persistence/)).